Biological Indicator for Steam

Biological Indicator for Steam
Biological Indicator for Steam

Biological Indicator for Steam Specification

  • Size
  • Standard
  • Equipment Type
  • Biological Indicator for Steam
  • Suitable For Use
  • Hospital, Laboratory, Pharmaceutical, Medical Device Sterilization
  • Technology
  • Steam Sterilization Monitoring
  • Portable
  • Yes
  • Material
  • Polypropylene tube with spore strip and growth media ampoule
  • Application
  • Steam Sterilization Process Monitoring & Validation
  • Use
  • Sterilization Validation
  • Storage Instructions
  • Store between 2C 25C, dry condition
  • Color
  • Clear tube, purple or clear media
  • Capacity
  • One per cycle/test
  • Function
  • Detects presence or absence of viable bacterial spores post sterilization
  • Condition
  • New
  • Shape
  • Cylindrical Ampoule
  • Real-Time Operation
  • No
  • Operation Mode
  • Incubation Post Exposure
  • Operating Type
  • Manual
  • Noise Level
  • Silent/None
  • Dimension (L*W*H)
  • Ampoule 10 x 60 mm (approx.)
  • Accuracy
  • 99%
  • Set Contains
  • 1 ampoule/indicator
  • Power
  • Not required (incubation requires incubator)
  • Adhesive Type
  • None
  • Wall Mounted
  • No
  • Feature
  • Visual color change, reliable microbial detection
 

Biological Indicator for Steam Trade Information

  • Minimum Order Quantity
  • 100 Vials Pieces
  • Payment Terms
  • Letter of Credit (L/C), Cash in Advance (CID), Cheque, Cash Advance (CA)
  • Supply Ability
  • 100 Pieces Per Week
  • Delivery Time
  • 7 Days
  • Sample Available
  • Yes
  • Sample Policy
  • Sample costs shipping and taxes has to be paid by the buyer
  • Main Export Market(s)
  • Asia
  • Main Domestic Market
  • All India
  • Certifications
  • FDA & ISO Certified
 

About Biological Indicator for Steam

Biological Indicator for Steam is often used for routine monitoring, qualification and load monitoring of a steam sterilizer. It is designed to demonstrate whether the conditions during a steam (autoclave) cycle were adequate to achieve a defined level of microbial inactivation. Biological Indicator for Steam can be availed from us in bulk on time.



Technical Specifications

Brand

SPS Medical & Sterintech

Usage/Application

Monitoring of Sterilization Process

Usages

Hospital, Pharma, Clinic & Laboratory



Steam Sterilization Monitoring

This indicator leverages a robust biological method for steam sterilization process validation, providing critical assurance in hospital, laboratory, and pharmaceutical settings. Its sensitive readout, based on microorganism viability, ensures that only successful cycles pass, offering a clear and simple result with color change technology.


Reliable Visual Readout

Featuring a clear tube and visual media, monitoring is effortlesspurple indicates sterilization failure, yellow signals success. With an accuracy of 99% and compliance with ISO and CE standards, users benefit from dependable microbial detection, enhancing process safety and reducing risk.


Convenient Use and Storage

The portable, single-use ampoule is simple to activate post-sterilization and requires only an incubator at the specified temperature. Store between 2C25C in dry conditions, protected from humidity above 70% RH. Each indicator is individually packed to support traceability and ease of handling.

FAQs of Biological Indicator for Steam:


Q: How do I use the Biological Indicator for Steam sterilization monitoring?

A: After running your steam sterilization cycle at 121C or 134C, activate the ampoule according to the instructions for use (IFU). Incubate it at 55C60C using a suitable incubator and observe for a color change from purple to yellow, which indicates whether viable spores are present.

Q: What is the readout method for this indicator and how reliable is it?

A: The indicator provides a visual color changepurple for non-sterilized, yellow for sterilizedoffering clear and immediate feedback. It achieves an accuracy rating of 99%, supported by ISO 11138 certification and CE marking.

Q: When should I check the results, and how long does incubation take?

A: Results should be checked after the recommended incubation period stated in the instructions for use, typically 24-48 hours. The ampoule must remain at 55C60C throughout incubation for an accurate determination.

Q: Where should these indicators be stored for optimal shelf life?

A: Store the indicators in a dry area between 2C25C with humidity below 70% RH. Proper storage ensures up to 12 months of shelf life from the manufacturing date.

Q: What are the benefits of using these indicators over chemical integrators?

A: Biological indicators directly measure sterilization efficacy by detecting viable spores, providing a higher level of validation than chemical integrators, which monitor physical parameters only. This increases safety and regulatory compliance.

Q: Are these ampoules compatible with all steam sterilizers?

A: Yes, they are suitable for use with steam sterilizers operating at 121C and 134C, making them versatile for hospital, laboratory, and pharmaceutical sterilization processes.

Tell us about your requirement
product

Price:

Quantity
Select Unit

  • 50
  • 100
  • 200
  • 250
  • 500
  • 1000+
Additional detail
Mobile number

Email

More Products in Sterilization Biological Indicator Category

Biological Indicator for Plasma

Biological Indicator for Plasma

Price 300 INR

Minimum Order Quantity : 100 Vials Pieces

Condition : New

Function : To verify plasma sterilization cycles

Shape : Cylindrical tube

Use : Sterilization assurance in plasma sterilizers

Biological Indicators ETO Steam Plasma

Biological Indicators ETO Steam Plasma

Price 150 INR / Vial

Minimum Order Quantity : 10 Pieces

Condition : New

Function : Detect sterilization process efficacy

Shape : Vial/Tube

Use : Sterilization validation

Biological Indicator for ETO

Biological Indicator for ETO

Price 150 INR

Minimum Order Quantity : N/a Piece

Condition : New

Function : Verification of ETO sterilization

Shape : Cylindrical Tube

Use : Sterilization validation and monitoring